Progress DataDirect for ODBC for Sybase IQ Wire Protocol Driver

    An asterisk (*) indicates support that was added in a hotfix or software patch subsequent to a release.

    Refer to the following resources for additional information:

    • Product Compatibility Guide: Provides the latest data source and platform support information. 
    • Fixes: Describes the issues resolved since general availability.  

    Version 8.0.2

      Enhancements
      • The driver is now compiled with a Visual Studio 2022 compiler for the Windows platforms. As a result, you must have Microsoft Visual C/C++ runtime version 14.40.33810 or higher on your machine to run the driver.
      • For AIX platforms, the ICU library files that are installed with the product have been upgraded to version 74.1. As a part of this upgrade, the ICU library file names have changed. For the 32-bit driver, the ICU file name has changed from libivicu28.a to libivicu.a. For the 64-bit driver, the ICU file name has changed from libddicu28.a to libddicu.a. This upgrade does not apply to the other UNIX platforms. This upgrade is available starting in build 08.02.1072 of the ICU library files.*
      • For Windows platforms, the ICU library files that are installed with the product have been upgraded to version 74.1. As a part of this upgrade, the ICU library file names have changed. For the 32-bit driver, the ICU file name has changed from ivicu28.dll to ivicu.dll. For the 64-bit driver, the ICU file name has changed from ddicu28.dll to ddicu.dll. This upgrade is available starting in build 08.02.1072 of the ICU library files.*
      • For Linux platforms, the ICU library files that are installed with the product have been upgraded to version 74.1. In addition, the ICU library file names have changed for Linux platforms. For the 32-bit driver on Linux, the ICU file name has changed from libivicu28.so to libivicu.so. For the 64-bit driver on Linux, the ICU file name has changed from libddicu28.so to libddicu.so. This upgrade does not apply to UNIX platforms. This upgrade is available starting in build 08.02.0965 of the ICU library files.*
      • The installer program has been enhanced to support Azul Zulu JRE 11. As a result of this change, the installer has ended support for platforms that do not support Java SE 8 or higher. The installer supports the following operating systems after the enhancement:
        • Windows 8.1 or higher
        • Windows Server 2012 RC2 or higher
        • UNIX/Linux: Any operating system on a machine using a JRE that is Java SE 8 or higher (LTS version), including Oracle JDK, OpenJDK, and IBM SDK (Java) distributions.
        Important: These changes do not affect the operating system requirements of the driver.*
      • The driver has been enhanced to include timestamp in the internal packet logs by default. If you want to disable the timestamp logging in packet logs, set PacketLoggingOptions=1. The internal packet logging is not enabled by default. To enable it, set EnablePacketLogging=1.
      • The Driver Manager for UNIX/Linux has been enhanced to support setting the Unicode encoding type for applications on a per connection basis. By passing a value for the SQL_ATTR_APP_UNICODE_TYPE attribute using SQLSetConnectAttr, your application can specify the encoding at connection. This allows your application to pass both UTF-8 and UTF-16 encoded strings with a single environment handle.
        The valid values for the SQL_ATTR_APP_UNICODE_TYPE attribute are SQL_DD_CP_UTF8 and SQL_DD_CP_UTF16. The default value is SQL_DD_CP_UTF8.     
      • A Password Encryption Tool, called ddencpwd, is now included with the product package. It encrypts passwords for secure handling in connection strings and odbc.ini files. At connection, the driver decrypts these passwords and passes them to the data source as required. See Password Encryption Tool (UNIX/Linux only) for details.
      Changed Behavior
      • The installer program now requires you to install a JRE that is Java SE 11 or higher before running the installer. In earlier versions, the JRE used by the installer program was included in the product. However, to avoid potential security vulnerabilities, the installer program no longer includes a JRE. Instead, the installer program uses the JRE in your environment to allow for the most secure version of a JRE to be used.

        Notes:

        • This change does not affect the JVM requirements for the driver. For the latest driver requirements, refer to the Product Compatibility Guide.
        • The installer program cannot remove the already installed JRE files from the install directory automatically. Remove them manually.
      • When calling the catalog functions in which the catalog name is passed as an argument, the driver now returns an empty result set instead of an error.
      • The product package no longer includes the ODBC Cursor library file (odbccurs.so) because it has some known security vulnerabilities that could potentially expose you to security risks.

        Note: The installer program cannot remove the ODBC Cursor library file automatically while installing a new version of the driver. Remove it manually.

      • The installer program has been updated to no longer install common components for drivers that do not use them. As a result, the installer program no longer installs the following common components for the Sybase IQ Wire Protocol driver:
        • OpenSSL library files, such as ivopenssl30.so, ddopenssl30.so, fips.so, and openssl.cnf.
        • Curl library files, such as libivcurl28.so and libddcurl28.so.

        If the files are not used by any other DataDirect driver on your machine, you can safely remove them from existing product directories.

      Notes, Known Issues, and Limitations
      • When the LoadTableFromFile() function is called, if the code page value specified in the configuration file, which is passed as an argument in LoadTableFromFile(), is different from the default code page value of the machine, the value set for the IANAAppCodePage connection attribute is replaced with it.

        This change may cause the driver to return the following error: "String data code page conversion failed." To work around it, set the SQL_ATTR_IANA_APP_CODE_PAGE statement attribute to the code page value specified in the configuration file.

      • The driver does not support specifying values for the same connection option multiple times in a connection string or DSN. If a value is specified using the same attribute multiple times or using both long and short attributes, the connection may fail or the driver may not behave as intended.
      • All of the Release 8.0 Core Components (header files, etc.) needed for development of ODBC applications on UNIX and Linux are installed into the /include directory created by the product installer.
        Please read the notices.txt file in the installation directory for licensing information regarding the ODBC Core Components. Contact your Progress DataDirect representative if you have any questions.
        Developers using programming languages other than C++: The DataDirect ODBC Driver Manager is a C++ shared library. The ODBC Driver Manager can be used with any language that supports loading a C++ shared library; however, if you are using a programming language other than C++, you must take additional steps to ensure that the C++ libraries are initialized properly when loaded. If you are not using C++, consult your compiler documentation for instructions on using C++ shared libraries with your application.
      • A default installation of the product on UNIX and Linux assumes that the value of the LANG environment setting is en_US. If your locale is not set to en_US, the drivers may not return error messages properly. In this case, you must create a symbolic link in the <Install_Dir>/locale directory that has the same value as the LANG environment setting. This link must point to the <Install_Dir>/locale/en_US directory.
      • The column attributes 1001 and 1002, which were assigned as DataDirect-specific attributes, were inadvertently used as system attributes by the Microsoft 3.0 ODBC implementation. Applications using those attributes must now use 1901 and 1902, respectively.
      • Because of inconsistencies in the ODBC specification, users attempting to use SQL_C_NUMERIC parameters must set the precision and scale values of the corresponding structure and the descriptor fields in the Application Parameter Descriptor.
      • One of the most common connectivity issues encountered while using IIS (Microsoft's Internet Information Server) concerns the use and settings of the account permissions. If you encounter problems using DataDirect drivers with an IIS server, refer to KnowledgeBase document number 4274 on the Progress DataDirect web site: http://knowledgebase.datadirect.com
      • You may receive a 126 error when adding or configuring a data source stored on a network location. This is caused by the settings of the User Account Control (UAC) security feature on Windows 10. To work around this issue:
        1. From the Start menu, type regedit in the search field; then, select regedit from the results list. The Registry Editor window opens.
        2. Navigate to the following registry subkey: HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\Policies\System
        3. Right-click on the subkey; then, select New > DWORD Value.
        4. Rename the new value EnableLinkedConnections.
        5. Right-click EnableLinkedConnections, and then click Modify. The Edit DWORD Value window opens.
        6. In the Value data field, type 1. Click OK.
        7. Close the Registry Editor; then, restart your computer.

        Important: Implementing this fix disables security safeguards that are designed to protect your machine. Before starting, refer to the following Microsoft documentation for potential risks associated with disabling the UAC feature: http://windows.microsoft.com/en-us/windows/what-are-user-account-control-settings

      • Some SQL implementations, such as PROGRESS, do not allow queries to contain the COUNT function without the DISTINCT set quantifier. For example, "SELECT COUNT(empid) FROM employees" is not a valid SQL query for PROGRESS. This type of query can be generated using Microsoft Access and results in an error.

      Version 7.1.6

      No features introduced 

        Version 7.1.5

        No features introduced

          Version 7.1.4

            Enhancements
            • The new KeepAlive connection option allows you to use TCP Keep Alive to maintain idle TCP connections.

            Version 7.1.3

            No features introduced

            Version 7.1.2

            No features introduced

            Version 7.1.1

            No features introduced 

            Version 7.1.0

            No features introduced 

          Connect any application to any data source anywhere

          Explore all DataDirect Connectors

          A product specialist will be glad to get in touch with you

          Contact Us